* Product Type: Ear thermometer WH-100A
Technical characteristics: (single or dual scale scale display) 1) Display range: 34.0 ~ 44.0oC/93.2 ~ 111.2oF 2) Accuracy: 0.2oC/0.4oF 3) Resolution: 0.1 4) Memory function: the last 10 measured values 5) Measurement time: 1 sec 6) The beep prompt function: measurement of the end of a buzzing Tips 7) Automatic shut down: no operation shut down automatically after 1 minute 8) Battery Type: AAA Alkaline Battery 2 9) Battery life: about 4,000 measurements 10) Dimensions: 134 x 70 x 34mm 11) Net Weight: 75g (including batteries) 12) Safety and Health 13) for each measurement need to use a one-time earmuffs Note: The foreign trade products, there are CE, ISO and other certificate. Usage: 1, open the battery cover, Qudiao insulating film. And then press the switch button on / recall, LCD display shows 188.8, representing a variety of mechanical thermometer normal and adequate electricity. 2,when the number of return to 0.00, when you can begin to measure. Infrared ear thermometer of the temperature into the ear canal where the first (as far as possible some depth), according to scan button, then release, when the hear the "drip" is heard later, that measurement is completed. (Attachment: For repeated measurements, it is recommended interval is about 1 minute,Appears on the screen should be the "ear"-shaped pattern and then for the next measurement, and requested the same as measuring the ear and the same location to minimize temperature differences. ) 3, measurement is completed, please click the back browser button (scan), display will show a group of from 9-0, a total of 10 digital temperature, and 9 show the temperature of the back is the latest measurement results. (Eg, from past to the present, a total of three times measured, then the screen will be displayed in turn: 935 degrees, 8 34.5 degrees, 735 degrees, 6 0.00 degrees, 0.00 degrees 5, 4, 0.00 ° 3 0.00 degrees, 2 0.00 degrees, a 0.00 degrees, 0 0.00 degrees. then 935 degrees is the last time you measured the temperature of 34.5 degrees is the second eight measurements of temperature, 735 degrees is the first time you test the temperature. When the 10 times measurements are used up when the system will automatically clear the memory, then from 9-0 there is not a new set of measurement opportunities, and so on continuously.) 4, after use, put it aside, the operating system will shut down automatically after 1 minute. |
![]() |